  • How long can AC2P carry my household appliances?

    Runtime = Capacity × DoD × η ÷ (load power+self-consumption power)
    Note:
    1. DoD refers to the Depth of Discharge, η is the local inverter efficiency. DoD=90%, η=85%.
    2. The above data is for reference ONLY.

  • Can a multi-socket expander/plug be connected to the AC of the machine to supply power to more loads?

    Yes, as long as the total load power does not exceed the maximum output power of the machine.

  • Can I use the wind generator to charge the machine?

    Not recommended. Due to the unstable air volume of the wind turbine, the output voltage and frequency of the wind turbine will be unstable and cannot be stabilized within the input range of our machine. It may be intermittent or even impossible to charge our machine directly.

  • Can the machine be placed sideways to save space?

    Do not. Long-term placement may loosen the internal structure. Upright placement is recommended.

  • Can AC2P charge lead-acid batteries and accumulators

    may
    1. If the customer has a lead-acid battery, the battery is equipped with an AC-DC adapter to charge the battery from the machine AC outlet
    2. You can also charge the battery directly from the DC 12V output outlet of the machine, Connect wire purchase link

  • Can I charge AC2P via DC/DC charger/MPPT controller /solar controller

    Yes, when charging AC2P via 12V/24V DC/DC charger/MPPT controller /solar controller, 24V is recommended. Because the charging power is higher

  • Power grid adaptive model

    When the weak power grid/generator of the customer's home charges our machine, because the AC output voltage or frequency of the weak power grid/generator is unstable, it is not possible to stably charge our machine, then the grid adaptive mode can be turned on to adapt to the customer's grid/generator

  • Hercules model

    AC2P can carry pure resistive loads up to 600W when turned on in Hercules mode, but two conditions need to be met
    1. The load must be pure resistive load
    2. Use it off-network

  • ECO mode

    Power saving mode: After the function is turned on, the machine AC or DC does not carry the device or the load power is too small, the machine will automatically turn off the AC or DC after a period of time, in order to reduce the power consumption of the machine and save power, the specific power and time can be set in the APP

  • Can I charge the AC2P with the T500 / How to charge AC2P with T200S

    1. No, use T200S to charge AC2P. The DC input voltage of AC2P ranges from 12V to 28V, while the maximum output voltage of T500 is 58.8V, beyond the DC input voltage range of AC2P, charging with T500 will damage AC2P
    2. The DC input port of AC2P is XT60, so it also needs a DC7909 to XT60 conversion line
    3. However, it is not recommended that T200S use AC2P to charge, and it is better to charge the machine directly with AC charging cable

  • Can I connect solar panels, car charging, and AC charging at the same time?

    AC2P supports AC+DC dual charging, but the DC has only one input port, so it only supports AC+ solar panel charging or AC+ car charging at the same time

  • Can a 12V/24V lead-acid battery charge AC2P

    1. Yes, charging cables with alligator clamps to XT60 are required and can be purchased from other platforms.
    2. When connecting the alligator clamps to the battery, do not connect the positive and negative terminals inversely

  • Does the machine support concurrent charging?

    Support simultaneous charging and discharging

  • How long does AC2P take to fully charge?

    Charging time (estimated) = (Capacity/Charging power) + Trickle charging time
    Trickle charging time for Bluetti power station is typically 0.5~1 hours

  • What is the maximum power output of AC2P?

    The rated output power of the AC is 300W, and the maximum output power of the AC+DC off-grid is 300W

  • What is the maximum charging power of AC2P?

    AC/AC+PV Maximum charging power:
    1. Standard mode 130W
    2. Silent mode 80W
    3. Fast charge mode 270W
    PV maximum charging power;
    1. Standard mode 130W
    2. Silent mode 80W
    3. Fast charge mode 200W
    Note: For AC+PV input, the PV input takes precedence

  • Can I connect different types of solar panels to AC2P?

    cannot

  • Can I use a third party solar panel to charge the AC2P?

    Yes, the solar panels must meet the following conditions:
    1. Total VOC:12V~28V
    2. Total power: 200W max
    3. With MC4 connectors
    4. Whether there is a micro inverter, micro-inverter can not directly charge AC2P, AC2P can only be micro-reverse charge through the AC wall charge
    Note: When VOC exceeds 28V, a third-party 24V DC/DC charger can be purchased to achieve solar charging.

  • How many solar panels can AC2P connect? Can the solar input current exceed 8.2A? Can the solar input power exceed 200 watts?

    1.AC2P can be connected to 1*PV120 or 1*PV200
    2. Solar input current can exceed 8.2A, our machine will limit the current, but beyond that is equivalent to a waste, the current can exceed, the voltage can not exceed
    3. Solar input power can exceed 200 watts, as long as the total PV VOC does not exceed 28V

  • What should be considered when charging AC2P from the generator?

    1. The output specifications, voltage and frequency of the generator need to be within the input range of the adapter. If it is unstable, you can open the grid adaptive mode in the APP for adaptation
    2. Whether the maximum output power of the generator meets the maximum AC input power of our machine, if not, our machine can adjust the charging mode to reduce the maximum AC input power
    3. The output of the generator is sine wave

  • What’s the difference between AC2P and EB3A in meeting various requirements?

    The main differences are as follows:
    1. battery capacity: AC2P capacity is 230.4Wh, while EB3A capacity is 268.8Wh
    2. Maximum output power: AC output power of AC2P is 300 W; While the AC output power of EB3A is 600W W.
    3. Charging power: The AC maximum charging power of AC2P is 270W; while that of EB3A is 430W.
    4. Weight and size: AC2P is smaller and lighter, making it easier to move.

  • How to maintain and store AC2P?

    1. When the SOC drops to 5%, please charge the product immediately.
    2. Before storing the product, please charge it to 60% SOC to keep it in the best condition. In addition, please turn off the equipment and disconnect all electrical connections.
    3. Store the product in a cool and dry place, away from flammable or combustible materials and gases.
    4. The power station can be safely stored in the temperature range of-20 C to 45 C (-4 F to 113°F). However, if the storage time exceeds one month, it is recommended to keep the ideal storage temperature around 30°C (86°F).
    5. Fully cycle the product every 3 months to keep the battery healthy.

  • Can I charge and discharge AC2A in a sub-zero environment?

    You can use the AC2P to charge your devices in cold weather, but please avoid recharging it below freezing. The operating temperature for AC2P is:
    Charging: 0℃~40℃ / 32℉~104℉
    Discharging: -20~40℃ / -4~104℉

  • Does AC2P support APP connection?

    Only Bluetooth connection APP is supported.

  • Is AC2P waterproof?

    No, please put it in a dry place. The working humidity range of AC2P is 10%~90%.

  • What is the switching time of UPS mode?

    Within 20ms.

  • Does AC2P have UPS function?

    Yes, the default standard UPS mode keeps the SOC at 100% all the time, which is mainly used for backup system.

  • Does AC2P have the capacity expansion function? Can AC2P be expanded with B80P, B300 and B230?

    AC2P has no capacity expansion function, so it can only be charged in charging mode of battery pack for false capacity expansion, and only supports false capacity expansion with B80P. B80P needs B80-AVIATION PLUG TO XT60 line to connect with AC2P in charging mode, buy the link

  • What cables and their lengths are included in purchasing AC2P?

    standard configuration:
    1. AC charging cable -L=1500mm (European, British and Australian regulations), L=1800mm (American and Japanese regulations).
    2. PV charging line -L=1500mmotherCar charging line -L=720mmType-C to Type-C line L=2000mm.

    Diagnose the Problem*(Please select at least one of the following):

    9 + 1 ?





    Please Select Language