Three-phase Output
Dual Votage
Capacity
Recommended MAX PV Array Power
BLUETTI is a leading provider of residential and portable energy storage solutions with patented technology and intellectual property rights. Its EP600 system is a safe, reliable and high-performance product that can store and release solar energy, provide off-grid power and interface with the grid. EP600 can optimize energy consumption patterns and enable homeowners to achieve energy savings and energy independence.
Whether you're permanently off the grid or have an occasional emergency, the EP600 ESS has no problem keeping your high-wattage appliances running at full capacity.
Couple the EP600 with your solar system, and you’re able to power your home with an endless supply of solar energy, living in a self-sufficient way and reducing your impact on the planet.
The EP600 ESS allows you to size its capacity to suit your needs. With just 2*B500 units (4,096Wh each), it can keep your essentials running for a long time during a power outage. Hook up 8 *B500 units, and you can rely on it to run your entire house for days.
864Wh / 1,000W
Output Power | 7,6kW |
Maximum Input Apparent Power | 11.5kVA |
Maximum Input Current | 50A |
Input Frequency | 50Hz |
On and Off-Grid Switching Time | <10ms |
Three Phase | L / N / PE |
Certifications | IEC62109-1, IEC62109-2, EN62109-1, EN62109-2,VDE-AR-N 4105, VDE V 0124-100, EN / IEC 61000-6-1, EN / IEC 61000-6-3, Rohs 2.0, IEC 60529 |
Output Power | 7,6kW |
Maximum Input Apparent Power | 11.5kVA |
Maximum Input Current | 50A |
Input Frequency | 50Hz |
On and Off-Grid Switching Time | <10ms |
Three Phase | L / N / PE |
Certifications | IEC62109-1, IEC62109-2, EN62109-1, EN62109-2,VDE-AR-N 4105, VDE V 0124-100, EN / IEC 61000-6-1, EN / IEC 61000-6-3, Rohs 2.0, IEC 60529 |
Output Power | 7,6kW |
Maximum Input Apparent Power | 11.5kVA |
Maximum Input Current | 50A |
Input Frequency | 50Hz |
On and Off-Grid Switching Time | <10ms |
Three Phase | L / N / PE |
Certifications | IEC62109-1, IEC62109-2, EN62109-1, EN62109-2,VDE-AR-N 4105, VDE V 0124-100, EN / IEC 61000-6-1, EN / IEC 61000-6-3, Rohs 2.0, IEC 60529 |
Still have questions? Don't hesitate to contact us for more answers.Contact Us
AC/AC+PV maximum charging power:
1. standard mode 470W
2. Silent mode 300W
3. Fast charging mode 900 W (JP)/950 W.
Maximum charging power of PV:
1. standard mode 470W
2. Silent mode 300W
3. Fast charging mode 500W W.
When AC+PV input, PV input will be given priority.
AC70P has no capacity expansion function, so it does not support direct capacity expansion with B80p, B300 and B230 battery packs. However, B80p, B300 and B230 can be connected with AC70P in charging treasure mode for false capacity expansion. B300 and B230 need P090D to DC7909 line and DC7909 bus to XT60 combination line to connect with AC70P in charging treasure mode.Purchase link
B80P needs B80-AVIATION PLUG TO XT60 line to connect with AC70P in charging treasure mode.Purchase link
Yes, the default standard UPS mode keeps the SOC at 100% all the time, which is mainly used for backup system.
Within 20ms.
No, please put it in a dry place. The working humidity range of AC70P is 10%~90%.
Only Bluetooth connection APP is supported.
1. When the SOC drops to 5%, please charge the product immediately.
2. Before storing the product, please charge it to 60% SOC to keep it in the best condition. In addition, please turn off the equipment and disconnect all electrical connections.
3. Store the product in a cool and dry place, away from flammable or combustible materials and gases.
4. The power station can be safely stored in the temperature range of-20 C to 45 C (-4 F to 113°F). However, if the storage time exceeds one month, it is recommended to keep the ideal storage temperature around 30°C (86°F).
5. Fully cycle the product every 3 months to keep the battery healthy.
Not recommended. Long-term placement may loosen the internal structure. It is recommended to place it upright.
You can use the AC70P to charge your devices in cold weather, but please avoid recharging it below freezing. The operating temperature for AC70P is:
Charging: 0℃~40℃ / 32℉~104℉
Discharging: -20~40℃ / -4~104℉
The main differences are as follows:
1. UPS: AC70p has it, but EB70S does not.
2. Battery capacity: AC70P capacity is 864Wh, while EB70S capacity is 716Wh.
3. Maximum output power: AC output power of AC70P is 1000 W; The AC output power of EB70SA is 800W (low voltage) /1000W (high voltage).
4. Charging power:; The AC maximum charging power of AC70P is 950 W, the PV maximum charging power is 500 W, and the PV input voltage ranges from 12 V to 58 V, which supports AC+PV dual charging. However, the maximum charging power of the EB70S adapter is 200W, the maximum charging power of the PV is 200 W, and the input voltage of the PV ranges from 12 V to 28 V, which does not support AC+PV dual charging.
5. Other functions: AC70P supports Bluetooth connection APP function and Hercules mode; And EB70S doesn't support it.
1. The output specification, voltage and frequency of the generator need to be within the input range of the adapter. If it is unstable, it can be adapted by opening the power grid adaptive mode in the APP.
2. Does the maximum output power of the generator meet the maximum AC input power of our machine? If not, our machine can adjust the charging mode to reduce the maximum AC input power.
3. The output of the generator is sine wave.
1.AC70P can be connected with 1-2 * PV 120, 1-2 * PV 200, 1 * PV 350 and 1 * PV 420.
2. It is best to connect all solar panels in series, because the AC 70pv input is in a wide voltage range of 12V~58V, and the maximum input current is only 10A, so the series voltage increases and the parallel current increases, so the series efficiency is higher. Pay attention not to mix different types of solar panels, otherwise the efficiency will be affected, and the solar panels will be damaged after a long time.
3. If the solar input current can exceed 10A, our machine will limit the current, but if it exceeds it, it will be wasted. The current can be exceeded, but the voltage cannot be exceeded.
4. The input power of solar energy can exceed 500 watts, as long as the total VOC of PV is ensured not to exceed 58V.
Yes, as long as the specifications of solar panels are in the following range:
1. Total VOC: 12V ~ 58V
2. Total power: 500W max.
3. with MC4 connector
4. Is there a micro-inverter? Micro-inverter can't directly charge AC70P, but AC70P can only be slightly charged by AC wall charging.
cannot
Not recommended. Due to the unstable air volume of the wind turbine, the output voltage and frequency of the wind turbine will be unstable and cannot be stabilized within the input range of our machine. It may be intermittent or even impossible to charge our machine directly.
Charging time (estimated) = (Capacity/Charging power) + Trickle charging time
Trickle charging time for Bluetti power station is typically 0.5~1 hours
Support the same charge and release.
AC70P supports AC+DC dual charging, but DC has only one input port, so it only supports AC+ solar panel charging or AC+ car charging at the same time.
1. yes, the DC input voltage range of AC70P is 12V~58V, and the maximum output voltage of T200S is 25.2V, which is within the DC input voltage range of AC70P, but the DC input port of AC70P is XT60, so a DC7909 to XT60 conversion line is needed.
2. However, it is not recommended to charge AC70P with an adapter. It is better to charge the machine directly with an AC charging cable.
1. Yes, you need the charging cable of alligator clamps to XT60, and other platforms will buy it themselves.
2. When the Alligator Clips are connected to the battery, be careful not to connect the positive and negative poles in reverse. The charging line of the alligator clamps to XT60 needs to be combined with the DC7909 line and the DC 7909 bus to XT60 line.
can
1. If the customer has a lead-acid battery, the battery is equipped with an AC-DC adapter to charge the battery from the AC outlet of the machine.
2. You can also charge the battery directly from the DC 12V output port of the machine. Connect the cable to buy the link
Yes. However, the max charging power would be limited to 100W / 200W.
Power saving mode: when this function is turned on, the AC or DC of the machine has no on-load equipment or the on-load power is too small, and the machine will automatically turn off the AC or DC after a period of time to reduce the self-consumption of the machine and save electricity. The specific power and time can be set in the APP.
AC70P can carry a pure resistive load of up to 2000W when Hercules mode is turned on, but two conditions need to be met:
1. The load must be purely resistive.
2. It needs to be used off the network
When the weak current grid/generator of a customer's home charges our machine, and the AC output voltage or frequency of the weak current grid/generator is unstable, we can turn on the grid adaptive mode to adapt to the customer's grid/generator.
Yes, as long as the total load power does not exceed the maximum output power of the machine.
Runtime = Capacity × DoD × η ÷ (load power+self-consumption power)
Note:
1. DoD refers to the Depth of Discharge, η is the local inverter efficiency. DoD=90%, η=85%.
2. The above data is for reference ONLY.
standard configuration:
1.AC charging cable -L=1500mm (British standard), L=1800mm (American, Japanese, European and Australian standard).
2. PV charging line -L=1500mm
3. Car charging line -L=720mm
other:
Lead-acid battery charging clip to cigarette lighter L=500mm
Cigarette lighter to DC5521 line (12V)-L=720mm
Combination of lead-acid battery charging line alligator clamps to DC7909 and DC7909 bus to XT60 L=1500mm+50mm.
Type-C to Type-C line L=2000mm.
B80P charging treasure mode output line B80-AVIATION PLUG TO XT60 line L=720mm.
B230 B300 charging treasure mode output line P090D to DC7909 and DC7909 mother seat to XT60 combination line L=1500mm+50mm.
Not recommended. The DC input ranges of D050S and AC70P are almost the same. The main function of D050S is to stabilize the voltage, not to increase the charging power. Adding D050S will increase the loss.D050S mainly charges AC200MAX, AC 200p, B230, B300 and B300s.
中国大陆
简体中文United Kingdom
English